Functional Description
Two timers are defined by default. For each timer, the following modes of operation are available:
- Free-running mode
The counter wraps after reaching its zero value, and continues to count down from the maximum value. This is the default mode.
- Periodic mode
The counter generates an interrupt at a constant interval, reloading the original value after wrapping past zero.
- One-shot mode
The counter generates an interrupt once. When the counter reaches 0, it halts until you reprogram it.