文档中心 > GR551x Datasheet/ Peripherals / Dual-Timer/ Functional Description Copy URL

Functional Description

Two timers are defined by default. For each timer, the following modes of operation are available:

  • Free-running mode

    The counter wraps after reaching its zero value, and continues to count down from the maximum value. This is the default mode.

  • Periodic mode

    The counter generates an interrupt at a constant interval, reloading the original value after wrapping past zero.

  • One-shot mode

    The counter generates an interrupt once. When the counter reaches 0, it halts until you reprogram it.